下死点绝对值监视装置 |
Bottom Dead Center Absolute Value Monitoring Device |
RM-7201(GX) |
 |
RM-7201 : |
A succeeding model of NEW SELBER VII (SEVEN) I can watch a change by color graphic indication in per hour of a bottom dead center. Consecutive records of bottom dead center data are possible with USB flash memory.
It is participated actively by traceability! |
CHARACTERISTICS |
Achieved high-speed tracking and high-reliability
High-speed tracking with monitoring function. The maximum speed is 2000 min-1 (spm). Conventional model is 1300 min-1 (spm). |
VISUAL MONITORING |
Adopted 5.7 inches color liquid crystal monitor. Achieved better view and more indication of the information for numeric values and waveforms.
It enables clear and wide view of ram乫s variation per hour with graph.
Newly adopted one-shot waveform indication function contributes to take necessary actions for a press machine or a stamping die by checking the motion of the stripper plate with waveform though the conventional model allows just to see the numerical values. |
DATA COLLECTION WITH PC, EASY DATA PROCESSING |
It stores consecutive B.D.C. data and easy to output the data.
The data is stored in the USB flush memory, which is available in the market. It allows easy transportation of the data from production site.
Large capacity type 128M stores 5 million shots data approx.
The flush memory data can be processed in the Excel files since it is stored as CSV file format.
Excel is a trademark of Microsoft Excel. |
Name |
new SELBER GX B.D.C. ABSOLUTE MONITORING DEVICE |
Type |
RM-7201 |
Sensor input |
2-channels RS-833H or RS-903H
Measuring range 600-2000μm
Installation range 800-1600μm |
Resolution |
1μm |
Indication |
5.7 inches color liquid crystal monitor 320/ 240dots |
Monitoring |
Standard / Previous value monitoring switching |
Setting |
Upper limit monitoring value, Lower limit monitoring value
(± 99μm against the standard value with 1μm step)
Numbers of sampling 1-100
Numbers of data cutoff 0-100 |
Sensor check |
Switching of Yes/No for detection of sensor malfunction |
Data storage |
Output B.D.C. value 1 channel or logger data 2 channels |
1. |
USB flash memory (Commercial item)
Large capacity type 128M stores 5 million shots data approx |
2. |
USB output by using USB connection cable (Commercial item) |
|
Input |
Start Input, Reset Input, Timing Input
NPN non-voltage open collector input (Drive current 15mA or more) |
Output |
Upper limit stop output, Lower limit stop output, Aux. output
Relay contact output NC-C-NO AC250V, 2A max. (Resistance load) |
Power for signals |
DC12V, 250mA Max. |
SPM |
3 /2000 min-1 (spm) |
Stroke length |
8mm or over |
Power supply |
AC100/240V |
Circum. Temp. |
0-40°C |
Cable length |
Sensor (RS-833H) 10cm
Connection cable 3-10m (Accessory cable 5m) |
Dims. |
220(W)x135(H)x136(D)mm approx.
(Excluding terminal block and extrusions) |
STANDARD ACCESSORIES |
Proximity sensor |
RS-833H |
2 pcs. |
Connection cable |
RS-835C 5m |
2 pcs. |
Proximity block |
2 pcs. |
Sensor fixing block |
2 pcs. |
Power cable 5 cores without plug |
5m |
Earth cable |
5m |
|
动态位移采集系统 |
Dynamic Displacement Acquisition System |
 |
RM-2200 is newly developed system to measure dynamic accuracy of press machines based on the know-how which has been developed by conventional unit RM-1100 with improved function and operability. It performs under Windows circumstances. It performs data acquisition more flexibly and performs waveform analysis. It has the function to export the data to other applications as well. |
Measurement mode |
It offers new standard for a press machine dynamic accuracy measurement as a highly relied and high performance expert tool. The data measurement circumstances can be built up for note book type PC easily.
High speed measurement : It will follow to 4000 min-1(spm)as Max.(Mode 1)
It performs trace waveform measurement for 1 shot easily with automatic scaling function. (Mode) |
Date conversion |
It achieved easy data conversion.
The data measured by RM-2200 can be converted to CSV files.
It enables to handle the data by using spreadsheet applications. |
|
自动废渣检出装置 |
Automatic Slug Detection Device |
 |
RM-1310 |
This device will detect the slugs coming up by detecting the displacement of stripper plate when slugs come up. The displacement is detected by the sensors, which are installed on the stripper plate.
This is the upgrade product of RM-1309S as a simplified model of MX series.
Monitoring accuracy : +/-1μm
(RM-1309S monitoring accuracy : +/-5μm) |
Characteristics |
Achieved a low price.
Quick replacement is achieved by interchangeability of sensor.
Timing sensor is not required since it has internal synchronization.
Digital type achieved simple operation. (There is no variation in operator.) |
Detection Method |
The slug, which is caught in upper or lower surface of the raw material will be crashed by stripper plate of the die which has spring loaded stopper at B.D.C. However, 20 to 40% of slug thickness (depends on material) will be remain and it will shift the position of stripper plate. This device will detect the displacement of the stripper plate by comparing with normal position.
This device will not be affected by the change of material thickness or rise in temperature of the unit since it compares the displacement of the stripper plate at every stroke.
This device is not be affected by the bound or spring load of the stripper plate due to bottom hold type system which only detects the lowest point of the stripper plate by using micro processor. |
SPECIFICATIONS |
Designation & Type |
NEW SELBER V RM-1310 |
Sensor principle |
Eddy current loss type, Proximity sensor RS-833H |
Displacement indication |
+/- 99μm LED 2 digits (1μm/digit, +/- indication) |
Monitor value indicatio |
99μm LED 2 digits (1μm/digit) |
Monitoring resolution |
+/-1μm |
Repeatabilit |
Less than 1μm |
Reaction to abnormality |
Error lamp turns on and output the stop signal |
Response speed |
Less than 12msec to output the stop signal |
Power consumption |
AC100 - 230V, 50/60Hz, Less than 8VA |
Circum. temperature |
0-50degrees |
Max. SPM |
30-3000min-1(spm) |
Sensor setting distance |
1.2 +/-0.3mm |
Output |
"Stop output" Relay contact (A, B contact) AC, 250V 2A |
Input |
"Reset input", "Start input", No-voltage contact or NPN open collector |
Cable length |
Proximity sensor : 10cm, Connection cable : 3m |
Dimensions |
110 (W) X 50 (H) X 120 (D) mm
(Excluding projections and fixing angles.) |
Accessories |
Proximity sensor RS-833H X 1 pc |
Connection cable RS-833C, 3m X 1 pc |
Power/Output cable 3m, 5 cores without connector X 1 pc |
Proximity block X 1 pc |
Sensor fixing angle X 1p |
M3 X 12mm Hex bolt X 2 pcs |
M5 X 15mm Hex bolt X 2 pcs |
Spring washer for M5 X 2 pc |
Washer for M5 X 2 pcs |
Nut for M2.6 X 8 pcs |
Spring washer for M2.6 X 8 pcs |
Operation manual X 1 set |
|
|
 |
|
|
|
 |